Skip to product information
Systellar RS485 Modbus communication card for MPPT-Compact, MPPT-Gen6 and MPPT-HV-300 solar charge controllers

RS485 / Modbus Communication Card for Systellar MPPT Solar Charge Controllers

Rs. 2,999.00
Sale price  Rs. 2,999.00 Regular price 

Add Modbus RTU monitoring and control to your Systellar MPPT charge controller

The Systellar RS485 / Modbus Card is a factory-supported optional interface that lets any external controller, IoT gateway, data logger, PLC, HMI or SCADA system read live data from — and write charging setpoints to — your Systellar MPPT solar charge controller.

The card communicates using the industry-standard Modbus RTU protocol over a 2-wire RS485 bus, so it works with virtually any monitoring hardware or software you already use. Supplied with its mating connector, ready to wire in.

Compatible with

  • Systellar MPPT-Compact Solar Charge Controllers
  • Systellar MPPT-Gen6 Solar Charge Controllers
  • Systellar MPPT-HV-300 Solar Charge Controllers

Note: this interface requires the charge controller to be supplied with the matching Modbus firmware. Please order this card together with your charge controller, or contact us at info@systellar.in with your controller serial number before ordering separately.

What you can read from the controller

  • Battery voltage
  • Battery current
  • PV (solar array) voltage
  • PV (solar array) current
  • Fault and status flags (bit-mapped)

What you can write to the controller

  • Battery end-of-charge voltage (V_BATT_EOC)
  • Battery trickle / float voltage (V_BATT_TRICKLE)
  • Maximum charging current (MAX_I_CHG)
  • Absorption mode duration, in minutes

Interface specifications

Protocol Modbus RTU
Physical layer RS485, 2-wire (2W), half duplex
Connections 3 wires — GND, D+, D-
Baud rate 9600 baud
Frame format 8 data bits, no parity, 1 stop bit (8-N-1)
Role Charge controller LC = Master
Default slave address 0x01 (changeable from the controller front panel)
Register width 16-bit u
Scaling Voltage and current in ×100 units (0–65535 = 0.00 to 655.35 V / A)
Supported function codes 0x03 Read Holding Registers, 0x04 Read Input Registers, 0x06 Write Single Register
Power supply to master Not provided — power your IoT device directly from the battery

Register map

Read registers (data from the charge controller)

Register Parameter Units
51 Faults / status flags Bit-mapped
201 Battery voltage Volt ×100
202 Battery current Amp ×100 203 PV voltage Volt ×100
204 PV current Amp ×100

Write registers (setpoints to the charge controller)

Register Parameter Units
102 V_BATT_EOC — battery end-of-charge voltage Volt ×100
103 V_BATT_TRICKLE — trickle / float voltage Volt ×100
104 MAX_I_CHG — maximum charging current
105 ABSORPTION_MODE_MINUTES — absorption duration Minutes

Each of these four registers must be written one at a time using a Write Single Register (0x06) command. The controller charges the battery at MAX_I_CHG until it reaches V_BATT_EOC, holds that voltage for ABSORPTION_MODE_MINUTES, then drops to V_BATT_TRICKLE.

Documentation — free download

Download the full interface specification and the refer

In the box

  • 1 × RS485 / Modbus interface card
  • 1 × Mating connector for field wiring

Technical support: info@systellar.in

Optional Accessories